All tenders
PublicOpenocds-h6vhtk-06da83United Kingdom· Tender

Turbine Hall Fire Detection and Suppression System

Sign in to view the buyer

The buyer and the original notice are hidden. Create a free account to unlock them.Create free account
Estimated value
GBP 300,000
Earliest action required
Checking…
Bid closes
10 Sept 2026
Submission method
Not stated at source

Uk Fts · published 07 Sept 2026 · last checked 07 Sept 2026 · 1 amendment recorded

Scope of works

The contractor shall provide a complete engineered fire detection and suppression system, including all labour, materials, plant, access equipment, design services, testing equipment, certification and documentation necessary to deliver a fully operational system. The protected scope comprises four individual turbine areas within the Turbine Hall. For tendering purposes, each turbine shall be assumed to have an approximate protected area of 15 m², giving an indicative total protected turbine area of approximately 60 m². Tenderers shall verify all dimensions, access constraints, hazard locations and coverage requirements during the site survey and shall base the final design on confirmed site measurements and risk assessment. • Site surveys and risk assessment of the Turbine Hall and protected turbine assets. • Design of the fire detection, alarm interface and suppression system. • Selection and supply of detectors, control panels, suppression equipment, pipework, nozzles, cylinders, pumps, valves, cabling, containment, signage and ancillary equipment. • Installation of all system components, including interfaces with existing fire alarm, plant control, shutdown, ventilation or building management systems where required. • Factory acceptance testing, site acceptance testing, commissioning and functional performance testing. • Provision of certification, operation and maintenance manuals, as-built drawings, cause-and-effect documentation and training. • Provision of warranty, defects support and proposals for ongoing inspection, testing and maintenance. 4. Regulatory and Standards Compliance The system and all works shall comply with all applicable UK legislation, regulations, approved guidance and recognised standards current at the date of tender and installation. The contractor shall identify and declare all applicable standards within their tender submission and shall state any proposed deviations. • Regulatory Reform (Fire Safety) Order 2005 and the duties of the Responsible Person. • BS 5839-1 for fire detection and fire alarm systems in non-domestic premises, including design, installation, commissioning and maintenance requirements. • Applicable BS EN 54 standards for fire detection and alarm components. • Applicable standards for the selected suppression technology, which may include BS EN 15004 for gaseous extinguishing systems, BS 8489 for industrial and commercial watermist systems, BS EN 12845 for sprinkler systems, or other relevant recognised standards appropriate to the proposed solution. • Where water mist is proposed, the system shall comply with BS 8489 or another applicable recognised standard for industrial and commercial water mist systems, together with manufacturer approvals, fire test evidence and any insurer requirements relevant to turbine or machinery-space oil-fire protection. • BS 7273 requirements for interfaces between fire detection systems and ancillary fire protection measures, where applicable. • Health and Safety at Work etc. Act 1974, CDM Regulations 2015, Electricity at Work Regulations 1989 and all applicable site safety requirements. • Manufacturer installation instructions, insurer requirements and industry best practice. 5. Technical Requirements 5.1 Fire Risk Basis The principal fire risk within the protected turbine areas arises from steam pipework operating at conditions and temperatures above the flash point of the oil used within the turbine systems. Oil pipework and steam pipework run adjacent to one another, increasing the likelihood that an oil leak, spray, mist or release could come into contact with hot steam pipework or other high-temperature surfaces and ignite. The fire detection and suppression design shall therefore be based on credible oil-release scenarios, including pressurised leakage, dripping, pooling, spray impingement, atomised mist and contact with hot pipework or adjacent hot surfaces. Tenderers shall explain how their proposed solution detects and suppresses fi

Type
Invitation to bid / open tender
Tender
Sector
Healthcare & Medical
Procedure
Open procedure
Classification
Not published at source

Source provenance (2)

Every portal notice that contributed to this record, with the values each one published. Where portals disagree, the originating notice is the published record.

Portal / referenceBuyerPublishedDeadlineValueMatch
uk_fts
ocds-h6vhtk-06da83
Sign in to view the buyer10 Aug 202610 Sept 2026GBP 300,000Published record
uk_fts
ocds-h6vhtk-06da83
Sign in to view the buyer07 Sept 202610 Sept 2026GBP 300,000Published record

Update history (1)

Field-level amendments detected by TenderHive monitoring at each harvest of the source portal.

  1. uk_fts3 fields changed
    • Buyer

      LONDONENERGY LTD

      Londonenergy Ltd

    • Status

      open

      closing_soon

    • Source notice URL

      https://www.find-tender.service.gov.uk/notice/075931-2026

      https://www.find-tender.service.gov.uk/notice/084636-2026

Key dates

  1. Published at source07 Sept 2026
  2. Submission deadline10 Sept 2026